Water Detectors

WFD Series Waterflow Detector

WFD Series water flow detectors are compatible with schedule 10 through 40 steel pipe, sizes 2 through 8 inch, and can be mounted in a vertical or horizontal position.

WFD Series water flow detectors are compatible with schedule 10 through 40 steel pipe, sizes 2 through 8 inch, and can be mounted in a vertical or horizontal position. WFD Series detectors consist of a rugged, NEMA 4-rated enclosure. Designed for both indoor and outdoor use, WFD Series detectors operate across a wide temperature range, from 32 to 120 °F.UL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance. The WFD Series detectors incorporate a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard’s unique sealed design is immune to dust and other contaminants. The WFD Series is designed to simplify installation. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field-replaceable.

Features & Benefits:
  • Two inch mounting hole provided in new WFD30-2 models
  • UL-listed models are NEMA 4 rated
  • Sealed retard mechanism immune to dust and other contaminants
  • Visual switch activation
  • Field-replaceable retard mechanism and SPDT switches
  • Rugged, dual SPDT switches enclosed in a durable terminal block
  • Accommodates up to 12 AWG wire
  • Designed for both indoor and outdoor use
  • 100% synchronization activates both alarm panel and local bell
  • Tamper-resistant cover screws
Certifications:
  • UL Listed S73
  • ULC CS169
  • CSFM 7770-1653:114
  • MEA Approved 167-93-E
  • FM Approved 3006195

Others

  • For Use With
    • Piping System
  • Regulatory Approvals
    • Standard with ULC models, optional for UL models, part no. 546-7000
  • Relay Contact Type
    • SPDT
  • Minimum Operating Ambient Temperature
    • 0 / 32 °C / °F
  • Maximum Operating Ambient Temperature
    • 49 / 120 °C / °F
  • Electrical Connection
    • UL-LISTED COMPATIBLE CONTROL PANEL

Others

  • For Use With
    • Piping System
  • Regulatory Approvals
    • Standard with ULC models, optional for UL models, part no. 546-7000
  • Relay Contact Type
    • SPDT
  • Minimum Operating Ambient Temperature
    • 0 / 32 °C / °F
  • Maximum Operating Ambient Temperature
    • 49 / 120 °C / °F
  • Electrical Connection
    • UL-LISTED COMPATIBLE CONTROL PANEL
  • For Use With : Piping System
  • Regulatory Approvals : Standard with ULC models, optional for UL models, part no. 546-7000
  • Relay Contact Type : SPDT
  • Minimum Operating Ambient Temperature : 0 / 32 °C / °F
  • Maximum Operating Ambient Temperature : 49 / 120 °C / °F
  • Electrical Connection : UL-LISTED COMPATIBLE CONTROL PANEL
Image
SKU
Description
alt
WFD30-2A
Water Flow Detector, 3in Steel Pipe, ULC
alt
WFD40A
Water Flow Detector, 4in Steel Pipe, ULC
alt
WFD80A
Water Flow Detector, 8in Steel Pipe, ULC
alt
WFD60
alt
WFD60A
Water Flow Detector, 6in Steel Pipe, ULC
alt
WFD40
alt
WFD25
Water Flow Detector, 2 1/2in Steel Pipe, UL
alt
WFD20
Water Flow Detector, 2in Steel Pipe, UL
alt
WFD50
Water Flow Detector, 5in Steel Pipe, UL
alt
WFD30-2
Water Flow Detector, 3in Steel Pipe, UL